发布时间:2024-4-9 10:37:00
BARCO巴可放映机常见故障代码:
5004
5005
5011
5043
5053
5073
5083
5180
5191
5212
5280
5283
5642
5644
5646
5647
5654
5657
5658
5800
5801
5802
5803
5807
5812
5811
5830
5836
代码 |
信息描述 |
信息中文描述 |
5004 |
“lamp - no communication” |
与灯箱无通信 |
5005 |
“lamp power supplies - Communication failed” |
与灯电源无通信 |
5011 |
“System-running in restricted access mode” |
系统在警告模式运行 |
5043 |
“cold mirror fan - speed too low” |
冷镜风扇速度低 |
5053 |
“engine fan - speed too low” |
引擎风扇速度低 |
5073 |
“lamp anode fan - speed too low” |
阳极风扇速度低 |
5083 |
“lamp cathode fan - speed too low” |
阴极风扇速度低 |
5180 |
“lamp house - not connected” |
灯箱未连接好 |
5191 |
“prism switch - warning(lens probably touches prism)” |
镜头位移过量 |
5212 |
“pump - speed too low” |
泵速度低 |
5280 |
“ambient - temperature too high” |
环境温度太高 |
5283 |
“ambient - temperature low” |
环境温度低 |
5642 |
“lamp power supplies - at least one lamp power supply could not be detected” |
一个灯电源检测不到 |
5644 |
but at least one lamp power is off |
灯电源打开,但一个灯电源关闭 |
5646 |
“Lamp set on =failed” |
开灯失败 |
5647 |
“lamp - lamp is off due to an error” |
关灯保护 |
5654 |
"Lamp run time-read failed" |
读取灯泡运行时间失败 |
5657 |
“lamp run time - exceeds maximum” |
灯超时 |
5658 |
"Lamp run time-read limits failed" |
读取灯泡运行时间失败 |
5800 |
“ti-boards - system status = fail” |
系统错-接触不良 |
5801 |
“ti-boards - security error, please authorize” |
安全问题--需安全认证 |
5802 |
“ti-boards - power up self test = fail” |
Ti板电源自检错 |
5803 |
"ti- |
|
5807 |
"ti-icp - read system status failed " |
Ti-ICP读系统状态失败 |
5812 |
"ti-icp - read satellite info failed " |
Ti-ICP读信息错 |
5811 |
“ti-boards - power-good = fail” |
Ti板电源问题 |
5830 |
"TI Link decrypter - No communication" |
TI连接解码-无通信, 可以放映 |
5836 |
5836 TI-rink-descryptor-security log error |
安全log问题- Enigma |
嘉贝得(北京)巴可放映机维修中心-为全国各省市影院提供以下维修业务:
1.ICP,PIB芯片重置和更换;
2.LD,LEQD板的更换;
3.光引擎部件的更换和维修;
4.风冷和水冷部件的更换和维修;
5.灯电源镇流器的更换和维修;
6.灯触发器的更换和维修;
7.视频文件的设置(包括3D);
8.播放通道的设置(包括3D);
9.调灯主件的更换与维修;
10.光学器件-导光管,反光镜的更换;
11.软件的升级;
12.触摸屏的更换;